System I - Conductive fluid, metal vessel, any consistency, rigid probe.
L101Heavy Duty Probe
Availability: KP, TS, TP, KS
Serves most applications, especially where flow, turbulence or agitation is present.Vessel must be metallic or contain a ground reference.
System II - Conductive fluid, metal vessel, any consistency, flexible probe.
L109 Flexible Wire Probe
Availability: TW, KW
For applications where physical restrictions prevent installation of rigid probe (e.g., minimum head room), or where probe length exceeds 236 inches.Available with tie-down or weight.Vessel must be metallic or contain a ground reference.
System III - Conductive fluid, non-metal vessel, any consistency, rigid probe.
L127 Flange Mounted Heavy Duty Dual Probe
Availability: KP, TS, TP, KS
This probe provides a ground reference and may be used where flow, turbulence, or agitation is present.
System IV - Conductive fluid, non-metal vessel, low consistency, flexible probe.
L113 Flexible Wire Probe with ground
Availability: TW, KW
Use where probe length exceeds 236 inches, or where physical restrictions prevent installation of rigid probe (e.g., minimum head room). Available with tie-down or weight.Stainless steel wire provides ground reference.For low consistency liquids.
System V - Conductive fluid, non-metal vessel, high consistency, flexible probe
L115 Flange Mounted Dual Wire Probe
Availability: TW, KW