Widest Range of Applications – the model L2610 is the ideal level transmitter, as it will operate in conjunction with process materials which range from low dielectric (insulating) products, such as refined oils, to conductive slurries; even sticky materials that tend to cling to the sensor. NULL-KOTE™ Circuitry – Makes the sensor immune to adverse effects of conductive coating build up. Designed to Survive – RF immune, vibration-proof, and conformal coated (tropicalized) circuit boards for additional protection – at no extra cost. Ten-Year Warranty – The only level instruments available with this unique assurance of quality. Wide Temperature Range – Standard process temperature range: -300 to + 500 F (-184 to + 260 C) | Explosion-Proof/Weatherproof Housing Standard– Class I, II, III, Div.1, Groups C, D, E, F, & G; NEMA 4 Factory Precalibrated – Field calibration, if needed, is quick and easy. No interaction between span and zero. Easy to Install – Probe and electronics install as single unit. No cable, delicate connectors, or separate enclosure. Built-In Self Diagnostics – provides assurance that the system is working properly. Easy-On Probe Connection – Automatically provides simple, fast installation and reliable operation without wires, connectors, or terminal strips. Simply screw probe into the housing. |
PRINCO’s L2610 NULL-KOTE™ analog RF level transmitter can be used to measure the level of virtually any process material, from low dielectric (insulating) products, such as refined oils, to conductive slurries – even viscous materials that cling to the probe.Advanced NULL-KOTE™ circuit design means accurate readings even when conductive materials build up on the probe. Superior temperature stability and noise immunity, conformal coated circuit boards, self-diagnostics and factory precalibration means accurate, reliable, easy-to-install level instrumentation. |
The L2610’s 4-20 mA dc output signal is proportional to the process level. Zero and span adjustments are non-interacting. Our Easy-On probe gives you reliable, automatic connection when the probe is screwed into the electronics housing. Span Range From 20 pF to 40,000 pF. Probe lengths from 1 inch to 150 feet, depending upon application.
Output Signal 4 to 20 mA dc.
Power Requirements Standard Models: 95/135 VAC, 50-60 HZ, 5 Watts 22/27 VDC, 2.2 Watts Optional Model: 230 VAC
Linearity/Accuracy ±0.5% typical
Repeatability ±0.1%
| 
|